中國(guó)臺(tái)灣EXETCH7410/7420安規(guī)綜合測(cè)試儀可選配內(nèi)建4組或8組高壓矩陣式掃描信道(7420, 7430 & 7440) 內(nèi)建50組程序記憶、每一組8個(gè)測(cè)試步驟可進(jìn)行程序記憶步驟的連結(jié)測(cè)試 測(cè)試線(xiàn)路阻抗自我歸零校整功能,確保測(cè)試結(jié)果的準(zhǔn)確性 可外接標(biāo)準(zhǔn)GPIB、USB & RS232、Printer Card 作控制 全范圍電壓輸出的穩(wěn)壓率在1%以?xún)?nèi) 中國(guó)臺(tái)灣EXTECH安規(guī)綜合分析儀7410的詳細(xì)介紹和規(guī)格:www.chem17.com/st240071/Index.html
7400 Series Electrical Safety Compliance Analyzer MODEL | 7410 | 7420 | 7430 | 7440 | AC WITHSTAND VOLTAGE | Output Rating | 5KVAC / 30mA | 5KVAC / 30mA | 5KVAC / 40mA | 5KVAC / 40mA | | Range | Resolution | Accuracy | Output Voltage,ACV | 0 - 5000 | 1 | ±(2% of setting + 5V) | Output Frequency | 50Hz / 60Hz ± 0.1%, User Selectable | Output Waveform | Sine Wave ,THD. < 2% (Resistive Load), Crest Factor = 1.3 - 1.5 | Output Regulation | ± (1% of output + 5V), From no load to full load | SETTINGS | Hi-Limit AC Current, mA | 0 - 30.00 | 0 - 30.00 | 0 - 40.00 | 0 - 40.00 | Resolution : 0.01, Accuracy : ±(2% of setting + 3counts) | Lo-Limit AC Current, mA | Range : 0 - 9.999 | Resolution : 0.001, Accuracy : ±(2% of setting + 3counts) | Ramp Time, second | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | Dwell Time, second | 0, 0.3 - 999.9 (0=continuous) | 0.1 | Arc Detection | The range is from 1 - 9 (9 is the most sensitive) | AC Current Offset, mA | 0 - 2.000 or Auto Set | DC WITHSTAND VOLTAGE | Output Rating | 6KVDC/9999µA | Output Voltage, DCV | 0 - 6000 | 1 | ±(2% of setting + 5V) | Output Ripple | < 5% (6KV / 9999 μA at Resistive Load) | SETTINGS | Hi-Limit DC Current, µA | 0 - 9999 | 1 | ±(2% of setting + 3counts) | Lo-Limit DC Current, µA | 0 - 999.9 | 0.1 | ±(2% of setting + 3counts) | Ramp Time, second | 0.1 - 999.9 | 0.1 | ± (0.1% of setting + 0.05s) | Dwell Time, second | 0, 0.4 - 999.9 (0=continuous) | 0.1 | Arc Detection | The range is from 1 - 9 (9 is the most sensitive) | DC Current Offset, ?A | 0 - 200.0 or Auto Set | Ramp High Current | ON/OFF, User Selectable | Charge - Low Current, µA | 0 - 350.0 or Auto Set | Discharge Time | ≦ 200 msec | INSULATION RESISTANCE | Output Rating | 1KVDC / 9999MΩ | Output Voltage, DCV | 100 - 1000 | 1 | ± (2% of setting + 3V) | Hi-Limit Resistance, MΩ | 0, 1 - 9999 (0=OFF) | 1 | 100 - 499V 1 - 999.9, ± (8% of setting + 2counts) 500 - 1000V 1 - 999.9, ± (2% of setting + 2counts) 1000 - 9999, ± (8% of setting + 2counts) | Lo-Limit Resistance, MΩ | 1 - 9999 | 1 | Delay Time, second | 0, 0.5 - 999.9 (0=continuous) | 0.1 | ±(0.1% + 0.05sec) | Charge - Low Current, µA | 0 - 3.500 or Auto Set | GROUND BOND (7440 ONLY) | Output Rating | 30A / 600mΩ, 8V | Output AC Current, A | 3.00 - 30.00 | 0.01 | ± (2% of setting +3 counts) | Output AC Voltage, V | 3.00 - 8.00 | 0.01 | ± (2% of setting +3 counts) at Open circuit | Output Frequency | 50Hz/60Hz ±100ppm, User Selectable | SETTINGS | Hi-Limit Resistance, mΩ | 0 - 150 (3 - 30A) | 1 | ± (2% of setting +2 counts) | Lo-Limit Resistance, mΩ | 0 - 600 (3 - 10A) | Lead Resistance Offset, mΩ | 0 -200 | 1 | ± (2% of setting +2 counts) | Dwell Time, second | 0, 0.5 - 999.9 sec (0=continuous) | 0.1 | ± (0.1% of setting + 0.05s) | MEASUREMENT | AC/DC Voltage, KV | 0 - 6.00 | 0.01 | ±(1.5% of reading ) > 500V ±(1.5% of reading + 1 count) < 500V | DC Voltage, V (IR) | 100 - 1000 | 1 | ±(1.5% of reading + 3V) | AC Current Range, mA | 0 - 3.500 | 0 - 3.500 | 0 - 3.500 | 0 - 3.500 | 3.00 - 30.00 | 3.00 - 30.00 | 3.00 - 40.00 | 3.00 - 40.00 | AC Current Resolution, mA | 0.001 / 0.01 | AC Current Accuracy, mA | ± (2% of reading + 3counts) | DC Current Range, µA | 0 - 350.0 | 0.1 | ± (2% of reading + 3counts) | 300 - 3500 | 1 | 3000 - 9999 | 10 | AC Current, A (GB) | 0 - 35.00 | 0.01 | ±(2% of reading+3counts) | Resistance, , MΩ(IR) | 1 - 9999 (Auto Range) | 0.001 0.01 0.1 1 | 100 - 499V 1 - 999.9, ± (8% of reading + 2counts) 500 - 1000V 1 - 999.9, ± (2% of reading + 2counts) 1000 - 9999, ± (8% of reading + 2counts) | Resistance, , mΩ (GB) | 0 - 600 | 1 | ±(2% of reading+2counts) | GENERAL | Input Voltage AC | 115V / 230Vac ± 15%, 50Hz / 60Hz ± 5%, max. current for 7410 model, max. current 6.3A for 7420 / 7430 / 7440 model | PLC Remote Control | Input : Test, Reset, Memory1, 2, 3 | Output : Pass, Fail, Processing | Memory | 50 memories, 8 steps/memory | Display | 20×2 LCD with back light | Key Lock | To prevent unauthorized alteration of the test Parameters | Calibration | Build-in software and external calibrated meters | Alarm Volume Setting | Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. | Rear Panel Output | YES | YES | YES | YES | Built-in Scanner | - | 8 CHANNELS | OPTION | OPTION | External Scanner | YES | YES | YES | YES | Smart GFI | YES | YES | YES | YES | Analog Meter | - | - | YES | YES | RS232 Interface | OPTION | OPTION | YES | YES | GPIB Interface | OPTION | OPTION | OPTION | OPTION | Printer Interface | OPTION | OPTION | OPTION | OPTION | TUV-GS listed | - | - | YES | YES | CE Compliance | - | - | YES | YES | Environment | 0-40℃, 20-80%RH | Dimension (W × H × D), mm | 430 × 133 × 300 | 430 × 133 × 500 | 430 × 133 × 500 | Net Weight | 12Kg | 18Kg | 22Kg | STANDARD ACCESSORIES | Power Cord(10A) | ×1 | Fuses | ×2 (Including a spare contained in the fuse holder) | Hipot Test Lead ,1.5m(1101) | ×1 | Return Test Cable(1102) | ×1 | Ground Bond Test Lead 30A, 1.5m (1103) | - | - | - | ×1 | Ground Bond Return Lead 30A, 1.5m (1104) | - | - | - | ×1 | Hipot Output Link Lead, 1.5m (1109) | - | ×8 | - | - | RS232 Link Cable 1.5m (1130) | - | - | ×1 | ×1 | Disk (RS232 test program) | - | - | ×1 | ×1 | *product specifications are subject to change without notice. | |